VB.net 调用带参数存储过程
--1:存储过程返回DataSet 的例子:
C# 代码 :通用类
public static int SingleSTCD(DateTime StartTime,DateTime EndTime,int SMTP,
string JL,string STDCD,string STCDSTR, out DataSet ds )
{
int ret=0;
ds=null;
OleDbConnection Constring=new OleDbConnection(Appraise.ConStr);
OleDbCommand cmd=new OleDbCommand(\"P_Get_STCD_SingleAppraise_XunQi\",
Constring);
try
{
OleDbDataAdapter ada=new OleDbDataAdapter();
cmd.CommandType=CommandType.StoredProcedure;
cmd.Parameters.Add(\"@StartTime\", OleDbType.DBTimeStamp).Value=StartTime ;
cmd.Parameters.Add(\"@EndTime\", OleDbType.DBTimeStamp).Value=EndTime ;
cmd.Parameters.Add(\"@SMTP\", OleDbType.Integer).Value=SMTP ;
cmd.Parameters.Add(\"@JL\", OleDbType.VarChar, 50).Value=JL ;
//cmd.Parameters.Add(\"@STDCD\", OleDbType.VarChar, 50).Value=STDCD ;
//评价标准
cmd.Parameters.Add(\"@STCDSTR\", OleDbType.VarChar, 8000).Value=STCDSTR ;
System.Data.DataSet data = new DataSet();
ada.SelectCommand = cmd;
ada.Fill(data,\"table\");
ds = data;
ret=ds.Tables[0].Rows.Count;
if ( ret ==-1 )
{
return -1000; //无数据
}
else
{
return ret;
}
}
catch(Exception e)
{
//数据库操作发生错误,返回错误代码
System.Diagnostics.Debug.WriteLine(e.Message);
return -1001;
}
finally
{
Constring.Close();
cmd.Parameters.Clear();
}
VB.net 调用:
Private Sub BindingDataGrid_Query()
Dim ds As System.Data.DataSet
Zehua.Water.Appraise.SingleSTCD(\"1999-5-1\", \"1999-9-1\", 1, \"Ⅲ\", \"\", \"50181300,50185050,50181350,50185100,50185150,50185200,50185250,
50181200,50185150,51282300\", ds)
DataGrid_Query.DataSource = ds
DataGrid_Query.DataBind()
End Sub
--1:存储过程返回数组字符串
REM 执行存储过程,返回一数组
Public Shared Function ExecuteSP_ToArrary(ByVal sConnString As String,
ByVal Text_STCD As String, ByVal Text_TIME As String,
ByRef TableInfo() As String)
Dim conn As OleDbConnection = New OleDbConnection(sConnString)
ReDim TableInfo(2)
Try
conn.Open()
Dim command As OleDbCommand = New OleDbCommand(\"P_GET_QueryValue\", conn)
command.CommandType = CommandType.StoredProcedure
Dim sqlParams() As OleDbParameter = {New OleDbParameter(\"@STCD\", Text_STCD),
New OleDbParameter(\"@GETM\", Text_TIME),
New OleDbParameter(\"@ReturnValue\", OleDbType.VarChar, 8000),
New OleDbParameter(\"@ReturnColumnCode\", OleDbType.VarChar, 8000),
New OleDbParameter(\"@ReturnColumnName\", OleDbType.VarChar, 8000)}
sqlParams(2).Direction = ParameterDirection.Output
sqlParams(3).Direction = ParameterDirection.Output
sqlParams(4).Direction = ParameterDirection.Output
Dim i As Integer = 0
While i < sqlParams.Length
command.Parameters.Add(sqlParams(i))
i += 1
End While
command.ExecuteNonQuery()
If sqlParams(2).Value.ToString().Length > 0 Then
TableInfo(0) = sqlParams(2).Value.ToString()
Else
End If
If sqlParams(3).Value.ToString().Length > 0 Then
TableInfo(1) = sqlParams(3).Value.ToString()
Else
End If
If sqlParams(4).Value.ToString().Length > 0 Then
TableInfo(2) = sqlParams(4).Value.ToString()
Else
End If
Catch ex As Exception
ZeHua.Log.exNoteBugs(ex, \"SigleStcdEdit.aspx\") \'sb.Append(ex.Message)
Finally
conn.Close()
End Try
End Function
- 上一篇: 单元测试辅助类
- 下一篇: 也说C#实现对Word文件读写